Quality Overhead Line fittings to Support Your Business
If you are looking for a complete range of overhead line fitting, Rayphen is always the best place. We will provide you our trusted overhead line fittings for your applications. Check it out!
More Details about Rayphen Overhead Line Fittings
- Strain Clamp
- Suspension Clamp
- Vibration Dampers
- Spacer Dampers
- Cable Cleats
- Mid span joint
- Compression Dead End
- Repair sleeve
Type No. | Conductor Dia.(mm) | Dimensions(mm) | U Bolt | Rated Failure Load(KN) | Weight (kg) | |||
R | C | M | Qty(pc) | Dia(mm) | ||||
NLL-1 | Φ5.0~15.5 | 8.0 | 19 | 16 | 2 | M12 | 40 | 0.85 |
NLL-2 | Φ8.2~17.0 | 9.0 | 22 | 16 | 3 | M12 | 70 | 1.5 |
NLL-3 | Φ11.4~20.0 | 10.0 | 24 | 16 | 4 | M14 | 70 | 2.74 |
NLL-4 | Φ13.6~25.0 | 12.5 | 30 | 18 | 4 | M16 | 100 | 3.96 |
NLL-5 | Φ16.0~32.0 | 16.0 | 36 | 22 | 5 | M16 | 120 | 5.65 |
NLL-6 | Φ28.5~46.5 | 23.5 | 50 | 24 | 6 | M16 | 120 | 9.0 |
Type | For AAC | For ACSR | Clamp range (mm) | U Bolt | Dimensions (mm) | Rated Failure Load(kN) | insulating cover | ||
No. | Dia. | C | M | ||||||
NLL-190 | 35-50 | 35-50 | Φ7.6-16.5 | 2 | M10 | 19.0 | 14 | 40 | NLLZ-190 |
NLL-230 | 95-150 | 70-95 | Φ8.5-20 | 2 | M12 | 23.0 | 16 | 50 | NLLZ-230 |
NLL-285 | 150-240 | 120-150 | Φ11.4-23 | 2 | M12 | 28.5 | 16 | 60 | NLLZ-285 |
NLL-320 | 240-300 | Φ12.7-26.5 | 2 | M12 | 32.0 | 16 | 60 | NLLZ-320 | |
NLL-320J | 150-185 | Φ12.7-26.5 | 2 | M12 | 32.0 | 16 | 70 | NLLZ-320J | |
NLL-350 | 240-300 | Φ13-30 | 2 | M14 | 35.0 | 16 | 80 | NLLZ-350 |
Catalog No. | Conductor Dia.(mm) | Dimensions(mm) | U Bolt | Rated Failure Load(KN) | Weight (kg) | |||||
L1 | L2 | R | C | M | Qty(pc) | Dia(mm) | ||||
NLD-1 | 5.0~10 | 150 | 120 | 6.5 | 18 | 16 | 2 | 12 | 20 | 1.3 |
NLD-2 | 10.0~14 | 205 | 130 | 8.0 | 18 | 16 | 3 | 12 | 40 | 2.1 |
NLD-3 | 14.1~18 | 310 | 160 | 11.0 | 22 | 18 | 4 | 16 | 70 | 4.6 |
NLD-4 | 18.1~23 | 410 | 220 | 12.5 | 25 | 18 | 4 | 16 | 90 | 7.0 |
Type | Conductor Dia.(mm) | Dimensions(mm) | Rated Failure Load (KN) | Weight (kg) | ||||
H | H1 | L | R | C | ||||
XGU-1 | 5.0~6.0 | 82 | 70 | 180 | 4.0 | 18 | 40 | 1.4 |
XGU-2 | 7.1~13.0 | 82 | 70 | 200 | 7.0 | 22 | 40 | 1.5 |
XGU-3 | 13.1~21.0 | 102 | 90 | 220 | 11.0 | 18 | 40 | 2.0 |
XGU-4 | 21.1~26.0 | 110 | 90 | 250 | 13.5 | 18 | 40 | 3.0 |
XGU-5A | 23.0~33.0 | 157 | 140 | 300 | 17 | 70 | 5.7 | |
XGU-5B | 23.0~33.0 | 137 | 120 | 300 | 17 | 20 | 70 | 5.4 |
XGU-6A | 34.0~45.0 | 163 | 140 | 300 | 23 | 70 | 6.1 | |
XGU-6B | 34.0~45.0 | 143 | 120 | 300 | 23 | 20 | 70 | 5.8 |
XGU-7B | 45.0~48.7 | 165 | 130 | 300 | 26 | 20 | 70 | 6.2 |
Catalog No. | Conductor Dia(mm) | Dimensions(mm) | Rated Failure Load(KN) | Weight (kg) | ||
R | C | M | ||||
CGH-2 | Φ5.0~12.4 | 9 | 19 | 16 | 40 | 1.1 |
CGH-3 | Φ12.4~20.0 | 11 | 22 | 16 | 40 | 1.4 |
CGH-4 | Φ20.0~26.0 | 13 | 28 | 16 | 40 | 1.9 |
CGH-5 | Φ26.0~34.0 | 17 | 36 | 16 | 70 | 2.5 |
CGH-6 | Φ34.0~40.0 | 21 | 45 | 16 | 70 | 2.8 |
CGH-7 | Φ40.0~46.0 | 23 | 48 | 16 | 70 | 3.2 |
Catalog No. | Conductor Dia(mm) | Dimensions(mm) | Rated Failure Load(KN) | ||
H | C | R | |||
XLU-1 | Φ8.0~14.0 | 113 | 20 | 7 | 40 |
XLU-2 | Φ14.0~20.0 | 125 | 22 | 10 | 70 |
XLU-3 | Φ20.0~26.0 | 145 | 28 | 13 | 80 |
XLU-4 | Φ26.0~32.0 | 150 | 36 | 136 | 80 |
XLU-5 | Φ32.0~38.0 | 160 | 42 | 19 | 100 |
Catalog No. | type | Conductor Dia(mm) | Dimensions(mm) | Rated Failure Load(KN) | Suitable calmp | |||
H | L | R | C | |||||
CSH-0422 | HSS-220 | Φ12.4~18.0 | 400 | 11 | 22 | 16 | 40 | CGH-3 |
CSH-0426 | HSS-280 | Φ18.0~26.0 | 400 | 13 | 28 | 16 | 40 | CGH-4 |
CSH-0734 | HSS-330 HSS-370 | Φ26.0~34.0 | 400 | 17 | 36 | 16 | 70 | CGH-5 |
CSH-0742 | HSS-480 | Φ34.0~40.0 | 400 | 21 | 45 | 16 | 70 | CGH-6 |
CSH-0746 | Φ40.0~46.0 | 400 | 23 | 48 | 16 | 70 | CGH-7 | |
CSH-0726 | CSH-4 | Φ20.0~26.0 | 400 | 13 | 28 | 16 | 70 | CGH-4 |
CSH-0734 | CSH-5 | Φ26.0~34.0 | 400 | 17 | 36 | 16 | 70 | CGH-5 |
CSH-1040 | CSH-1040 | Φ34.0~40.0 | 400 | 20 | 42 | 18 | 100 | CGH-1040 |
CSH-1046 | CSH-6 | Φ40.0~46.0 | 400 | 23 | 48 | 18 | 100 | C6GH- |
Catalog No. | Suitable Conductor | Dimensions(mm) | Weight (kg) | ||||||
D1 | D2 | A | H | L1 | L2 | L | |||
FR-1 | 7.0~12.0 | 48 | 48 | 50 | 81 | 138 | 118 | 429 | 2.54 |
FR-2 | 11.0~20.0 | 48 | 48 | 50 | 81 | 138 | 118 | 429 | 2.61 |
FR-3 | 18.0~28.0 | 57 | 57 | 60 | 91 | 167 | 146 | 505 | 5.00 |
FR-4 | 23.0~36.0 | 64 | 64 | 60 | 97 | 218 | 163 | 550 | 6.00 |
FR-5 | 33.0~38.0 | 64 | 64 | 70 | 127 | 218 | 163 | 550 | 7.90 |
FR-6 | 36.0~40.0 | 74 | 74 | 70 | 127 | 325 | 325 | 650 | 11.00 |
Catalog No. | Conductor Section Area(mm²) | Fig No. | Dimensions(mm) | Steel Wire Specification | Weight (kg) | |||||
Steal Wire | AAC,ACSR | D | A | H | L1 | L1 | ||||
FD-1 | / | 35~50 | Fig.2 | 40 | 40 | 40 | 95 | 300 | 7/2.6 | 1.5 |
FD-2 | / | 70~95 | Fig.1 | 46 | 45 | 55 | 130 | 370 | 7/3.0 | 2.4 |
FD-3 | / | 120~150 | Fig.1 | 56 | 60 | 65 | 150 | 450 | 19/2.2 | 4.5 |
FD-4 | / | 185~240 | Fig.1 | 62 | 60 | 70 | 175 | 500 | 19/2.2 | 5.6 |
FD-5 | / | 300~500 | Fig.1 | 67 | 70 | 70 | 200 | 550 | 19/2.6 | 7.2 |
FD-6 | / | 500~630 | Fig.1 | 70 | 70 | 75 | 200 | 550 | 19/2.6 | 8.6 |
FG-35 | 35 | / | Fig.2 | 42 | 45 | 50 | 100 | 300 | 7/3.0 | 1.8 |
FG-50 | 50 | / | Fig.2 | 46 | 45 | 50 | 130 | 350 | 7/3.0 | 2.4 |
FG-70 | 70 | / | Fig.1 | 56 | 50 | 60 | 150 | 400 | 19/2.2 | 4.2 |
FG-100 | 100 | / | Fig.1 | 62 | 60 | 65 | 175 | 500 | 19/2.2 | 5.9 |
Type | Suitable conductor | Clamp groove R | Conductor distance | Weight(kg) |
FJZ-240/20 | LGJ-180/10~45 | 8.5 | 400 | FJZ-240/20 |
FJZ-240/22 | LGJ-240/30~55 | 9.6 | 400 | FJZ-240/22 |
FJZ-240/24 | LGJ-300/20~70 | 10.0 | 400 | FJZ-240/24 |
FJZ-240/27 | LGJ-400/20~50 | 12.0 | 400 | FJZ-240/27 |
FJZ-240/30 | LGJ-500/35~65 | 13.0 | 400 | FJZ-240/30 |
FJZ-245/20 | LGJ-185/10~45 | 8.5 | 450 | FJZ-245/20 |
FJZ-245/22 | LGJ-240/30~55 | 9.6 | 450 | FJZ-245/22 |
FJZ-245/24 | LGJ-300/20~70 | 10.0 | 450 | FJZ-245/24 |
FJZ-245/27 | LGJ-400/20~50 | 12.0 | 450 | FJZ-245/27 |
FJZ-245/30 | LGJ-500/35~65 | 13.0 | 450 | FJZ-245/30 |
FJZ-250/30 | LGJ-500/35~65 | 13.0 | 500 | FJZ-250/30 |
FJZ-250/33 | LGJ-600/45 | 15.5 | 500 | FJZ-250/33 |
FJZ-250/36 | LGJ-720/50 | 17.1 | 500 | FJZ-250/36 |
Type | Suitable conductor | Dimensions(mm) | Weight(kg) |
L | |||
FJZD4-45/300 | LGJ-300 | 450 | 7.50 |
FJZD4-45/400 | LGJ-400 | 450 | 7.50 |
FJZD4-50/630 | LGJ-630/55 | 500 | 9.50 |
FJZD4-50/720 | LGJ-720/50 | 500 | 9.80 |
Type | Suitable conductor | Dimensions(mm) | Weight(kg) |
L | |||
FJZD4-45/300 | LGJ-300 | 450 | 7.50 |
FJZD4-45/400 | LGJ-400 | 450 | 7.50 |
FJZD4-50/630 | LGJ-630/55 | 500 | 9.50 |
FJZD4-50/720 | LGJ-720/50 | 500 | 9.80 |
Type No | Suitable busbar Dia.(mm) | Main Dimensions(mm) | ||
A | R | L | ||
MRJ-4/120 | Φ18.1~22.0 | 50 | 11 | 120 |
MRJ-5/120 | Φ23.0~29.0 | 60 | 14 | 120 |
MRJ-6/120 | Φ29.1~35.0 | 70 | 17 | 120 |
MRJ-4/200 | Φ18.1~22.0 | 50 | 11 | 200 |
MRJ-5/200 | Φ23.0~29.0 | 60 | 14 | 200 |
MRJ-6/200 | Φ29.1~35.0 | 70 | 17 | 200 |
MRJ-4/400 | Φ18.1~22.0 | 50 | 11 | 400 |
MRJ-5/400 | Φ23.0~29.0 | 60 | 14 | 400 |
MRJ-6/400 | Φ29.1~35.0 | 70 | 17 | 400 |
MRJ-9/120 | Φ45.0~49.0 | 60 | 24 | 120 |
MRJ-9/200 | Φ45.0~49.0 | 60 | 24 | 200 |
MRJ-9/400 | Φ45.0~49.0 | 60 | 24 | 400 |
MRJ-10/200 | Φ50.0~55.0 | 70 | 26 | 200 |
MRJ-10/400 | Φ50.0~55.0 | 70 | 26 | 400 |
Type | Suilable conductor | Φ | C | B | Bolt | Note |
JGH-01 | Φ55-65 | 65 | 130 | 75 | 2-M12 | High-voltage one core Flexibility cable cleat |
JGH-0 | Φ65-80 | 80 | 130 | 75 | 2-M12 | |
JGH-1 | Φ80-100 | 100 | 150-165 | 80 | 2-M12 | |
JGH-2 | Φ100-120 | 120 | 184-196 | 80 | 2-M12 | |
JGH-3 | Φ120-136 | 136 | 190 | 80 | 2-M12 | |
JGH-4 | Φ136-160 | 160 | 210 | 90 | 2-M12 |
Type | Suilable conductor | Φ | C | B | Bolt |
JGW-0 | Φ65-75 | 75 | 115 | 60 | 2-M12 |
JGW-1 | Φ75-84 | 84 | 120 | 80 | 2-M12 |
JGW-2 | Φ85-94 | 94 | 130 | 80 | 2-M12 |
JGW-3 | Φ95-104 | 104 | 140 | 80 | 2-M14 |
JGW-4 | Φ105-114 | 114 | 150 | 80 | 2-M14 |
JGW-5 | Φ115-124 | 124 | 160 | 90 | 2-M14 |
JGW-6 | Φ125-134 | 134 | 175 | 90 | 2-M16 |
JGW-7 | Φ135-150 | 146 | 190 | 90 | 2-M16 |
JGW-8 | Φ145-160 | 160 | 210 | 90 | 2-M12 |
Rigidity | flexibility | Suilable conductor | Φ | C | Bolt |
JGP-1 | JGPH-1 | 3×Φ45-Φ55 | 55 | 150 | 2-M12 |
JGP-2 | JGPH-2 | 3×Φ55-Φ68 | 68 | 186 | 2-M12 |
JGP-3 | JGPH-3 | 3×Φ68-Φ80 | 80 | 224 | 2-M14 |
JGP-4 | JGPH-4 | 3×Φ80-Φ90 | 90 | 245 | 2-M12 |
JGP-5 | JGPH-5 | 3×Φ90-Φ100 | 100 | 280~300 | 2-M12 |
JGP-6 | JGPH-6 | 3×Φ100-Φ114 | 114 | 290 | 2-M12 |
JGP-7 | JGPH-7 | 3×Φ115-Φ125 | 125 | 310 | 2-M12 |
JGP-8 | JGPH-8 | 3×Φ125-Φ136 | 136 | 340 | 2-M12 |
JGP-9 | JGPH-9 | 3×Φ136-Φ150 | 150 | 360 | 2-M12 |
JGP-10 | JGPH-10 | 3×Φ150-Φ160 | 160 | 380 | 2-M12 |
Rigidity | Flexibility | Suilable conductor |
JGP-1F | JGPH-1F | 3×Φ75-Φ84 |
JGP-2F | JGPH-2F | 3×Φ85-Φ94 |
JGP-3F | JGPH-3F | 3×Φ95-Φ104 |
JGP-4F | JGPH-4F | 3×Φ105-Φ114 |
JGP-5F | JGPH-5F | 3×Φ115-Φ124 |
JGP-6F | JGPH-6F | 3×Φ125-Φ134 |
JGP-7F | JGPH-7F | 3×Φ135-Φ146 |
Type | Suitable Conductor | Dimensions(mm) | Grip strength (≥KN) | Weight (kg) | |||
Standard | OD(mm) | D | d | L | |||
JY-150L | LJ-150 | 15.75 | 30 | 17.5 | 280 | 22 | 0.35 |
JY-185L | LJ-185 | 17.50 | 32 | 19.0 | 310 | 27 | 0.44 |
JY-210L | LJ-210 | 18.50 | 34 | 20.0 | 330 | 31 | 0.6 |
JY-240L | LJ-240 | 20.00 | 36 | 21.5 | 350 | 34 | 0.65 |
JY-300L | LJ-300 | 22.40 | 40 | 24.0 | 390 | 45 | 0.85 |
JY-400L | LJ-400 | 25.90 | 45 | 27.5 | 450 | 58 | 1.21 |
JY-500L | LJ-500 | 29.12 | 52 | 30.5 | 510 | 73 | 1.92 |
JY-630L | LJ-630 | 32.67 | 60 | 34.0 | 570 | 87 | 2.95 |
JY-800L | LJ-800 | 36.90 | 65 | 38.5 | 650 | 110 | 3.75 |
Catalog No. | Suitable Conductor | Dimensions(mm) | Slip Strength (≥KN) | ||||
D1 | D2 | D3 | C | L2 | |||
NY-95/15 | LGJ-95/15 | 26 | 14 | 16 | 20 | 55 | 33.5 |
NY-95/20 | LGJ-95/20 | 26 | 14 | 16 | 20 | 55 | 35.5 |
NY-120/20 | LGJ-120/20 | 30 | 14 | 16 | 20 | 55 | 39.0 |
NY-120/50 | LGJ-120/50 | 30 | 14 | 16 | 20 | 55 | 45.5 |
NY-150/20 | LGJ-150/20 | 30 | 14 | 16 | 22 | 65 | 44.0 |
NY-150/25 | LGJ-150/25 | 30 | 14 | 16 | 22 | 65 | 51.5 |
NY-150/35 | LGJ-150/35 | 30 | 16 | 16 | 22 | 65 | 62.0 |
NY-185/25 | LGJ-185/25 | 32 | 14 | 16 | 22 | 65 | 56.5 |
NY-185/30 | LGJ-185/30 | 32 | 16 | 16 | 22 | 65 | 61.5 |
NY-185/45 | LGJ-185/45 | 34 | 18 | 18 | 24 | 70 | 76.5 |
NY-240/30 | LGJ-240/30 | 36 | 16 | 18 | 24 | 70 | 72.0 |
NY-240/40 | LGJ-240/40 | 36 | 16 | 18 | 24 | 70 | 79.0 |
NY-240/55 | LGJ-240/55 | 36 | 20 | 20 | 26 | 78 | 97.0 |
NY-300/15 | LGJ-300/15 | 40 | 14 | 16 | 22 | 65 | 65.0 |
NY-300/20 | LGJ-300/20 | 40 | 14 | 18 | 24 | 70 | 72.0 |
NY-300/25 | LGJ-300/25 | 40 | 14 | 18 | 24 | 70 | 79.5 |
NY-300/40 | LGJ-300/40 | 40 | 16 | 18 | 24 | 70 | 88.0 |
NY-300/50 | LGJ-300/50 | 40 | 18 | 18 | 24 | 70 | 98.5 |
NY-300/70 | LGJ-300/70 | 42 | 22 | 20 | 26 | 78 | 122.0 |
NY-400/20 | LGJ-400/20 | 45 | 14 | 18 | 24 | 70 | 84.5 |
NY-400/25 | LGJ-400/25 | 45 | 14 | 18 | 24 | 70 | 91.0 |
NY-400/35 | LGJ-400/35 | 45 | 16 | 20 | 26 | 78 | 99.0 |
NY-400/50 | LGJ-400/50 | 45 | 20 | 20 | 26 | 78 | 117.0 |
NY-400/65 | LGJ-400/65 | 48 | 22 | 22 | 26 | 78 | 128.5 |
NY-400/95 | LGJ-400/95 | 48 | 26 | 24 | 30 | 80 | 163.0 |
Catalog No. | Suitable Conductor | Dimensions(mm) | Slip Strength (≥KN) | ||||
D1 | D2 | D3 | C | L2 | |||
NY-500/35 | LGJ-500/35 | 52 | 16 | 22 | 26 | 78 | 114.0 |
NY-500/45 | LGJ-500/45 | 52 | 18 | 22 | 26 | 78 | 122.0 |
NY-500/65 | LGJ-500/65 | 52 | 22 | 22 | 26 | 78 | 146.5 |
NY-630/45 | LGJ-630/45 | 60 | 18 | 22 | 26 | 78 | 141.5 |
NY-630/55 | LGJ-630/55 | 60 | 20 | 24 | 30 | 80 | 156.5 |
NY-630/80 | LGJ-630/80 | 60 | 24 | 24 | 30 | 80 | 183.5 |
NY-720/50 | LGJ-720/50 | 60 | 20 | 24 | 30 | 80 | 163.0 |
NY-720/65 | LGJ-720/65 | 60 | 22 | 24 | 30 | 80 | 176.0 |
NY-800/55 | LGJ-800/55 | 65 | 20 | 24 | 30 | 80 | 183.0 |
NY-800/70 | LGJ-800/70 | 65 | 22 | 26 | 34 | 90 | 197.0 |
NY-800/100 | LGJ-800/100 | 65 | 26 | 26 | 34 | 90 | 229.0 |
Catalog No. | Suitable Conductor | Dimensions(mm) | Slip Strength (≥KN) | ||||
D1 | D2 | D3 | C | L2 | |||
NY-150/25BG | JL/LB20A-150/25 | 32 | 16 | 16 | 22 | 65 | 51.5 |
NY-150/35BG | JL/LB20A-150/35 | 16 | 16 | 22 | 65 | 62.0 | |
NY-185/25BG | JL/LB20A-185/25 | 36 | 16 | 16 | 22 | 65 | 56.5 |
NY-185/30BG | JL/LB20A-185/30 | 16 | 16 | 22 | 65 | 61.5 | |
NY-240/30BG | JL/LB20A-210/30 | 38 | 18 | 18 | 24 | 70 | 72.0 |
NY-240/40BG | JL/LB20A-210/40 | 18 | 18 | 24 | 70 | 79.0 | |
NY-240/55BG | JL/LB20A-210/55 | 38 | 20 | 20 | 26 | 78 | 97.0 |
NY-300/25BG | JL/LB20A-300/25 | 42 | 16 | 18 | 24 | 70 | 79.5 |
NY-300/40BG | JL/LB20A-300/40 | 18 | 18 | 24 | 70 | 88.0 | |
NY-300/50BG | JL/LB20A-300/50 | 18 | 18 | 24 | 70 | 98.5 | |
NY-300/70BG | JL/LB20A-300/70 | 45 | 22 | 20 | 26 | 78 | 122.0 |
NY-400/25BG | JL/LB20A-400/25 | 48 | 18 | 18 | 24 | 70 | 91.0 |
NY-400/35BG | JL/LB20A-400/35 | 18 | 20 | 26 | 78 | 99.0 | |
NY-400/50BG | JL/LB20A-400/50 | 20 | 20 | 26 | 78 | 117.0 | |
NY-400/65BG | JL/LB20A-400/65 | 22 | 22 | 26 | 78 | 128.5 |
Type | Suitable Conductor | Dimensions(mm) | Weight (kg) | ||
D | R | L | |||
JX-25G | GJ-25 | 14 | 3.5 | 100 | 0.09 |
JX-35G | GJ-35 | 16 | 4.2 | 100 | 0.11 |
JX-50G | GJ-50 | 18 | 4.5 | 100 | 0.15 |
JX-55G | GJ-55 | 20 | 5.1 | 130 | 0.24 |
JX-70G | GJ-70 | 22 | 5.8 | 120 | 0.26 |
JX-80G | GJ-80 | 24 | 6.0 | 150 | 0.40 |
JX-100G | GJ-100 | 26 | 7.0 | 140 | 0.41 |
JX-120G | GJ-120 | 28 | 7.5 | 170 | 0.58 |
JX-135G | GJ-135 | 32 | 8.0 | 160 | 0.75 |
JX-165G | GJ-165 | 34 | 8.0 | 185 | 1.02 |
Send Inquiry

Let Rayphen Help You Improve Your Business
Rayphen is your reliable and one-stop-shop provider of overhead line fittings. We are experts in manufacturing overhead line fittings for more than 14 years.
Rayphen overhead line fittings are also named as overhead line accessories or overhead line hardware. Whether you are in the electricity distribution network industry, Rayphen overhead line fittings will satisfy your needs.
The inclusion of our overhead line hardware is a wide range of steel fittings. So, you can use Rayphen overhead line fittings for constructing an overhead line.
You can be sure that all of our overhead line fittings are hot-dip galvanized coatings according to BS EN ISO 1461.
Rayphen Overhead Lines Fittings has been exported to over 200 global clients and installed to electric power project in the world.
Rayphen Overhead Lines Fittings is manufactured with high-quality raw material.
Rayphen has over 14 years of Overhead Lines Fittings manufacturing experience.
Overhead Lines Fittings manufactured by Rayphen is 100% strictly tested before shipment.
Rayphen Overhead Line Fittings
At Rayphen, you can find various types of overhead line fittings we offer. Depending on your applications, you can always trust our string insulator, suspension clamp, tension clamp, strain clamp, compression sleeves, spacer damper, vibration dampers, Stockbridge damper, cable cleats, mid span joint, and compression dead end.
Each Rayphen overhead line hardware is durable, functional, and has its own advantageous features. Rayphen overhead line fittings are manufactured and designed for the electric connection and mechanical attachment.
Also, if you want to protect the insulators and conductors from stress and other mechanical forces, then Rayphen overhead line accessories are the best answer.
What’s more, our Rayphen overhead line fittings are designed to streamline the transfer of electric loads in a conductor. You can use overhead line fittings to secure the conductor and the cable through the slip-hole.
Rayphen overhead line fittings ensure that the main components of the overhead lines work smoothly as expected.
Rayphen is the best overhead line fittings manufacturer in China for more than 14 years. You can be sure that each and every overhead line fitting we produced conforms to the latest IEC 61284:1997 BS 3288-1:2014 standards and are manufactured with the best quality raw materials.
There are many processes to make each type of overhead line fitting such as casting, cold punch, forged, welding, heating, and more.
To make every step very well, Rayphen successfully passed the type testing, mechanical testing, tensile testing, electrical testing, and dimension testing as well as the galvanizing testing.
Our expert and professional team do 100% testing for any overhead line fitting before we deliver.
Rayphen can guarantee you defect-free products because our quality control team have made sure a 100% full inspection.
Contact us now!